Toshiba VF-nC1 Portable Generator User Manual


 
E6581090
K-6
11
  Acceleration/deceleration time parameters
Title
Communication
No.
Function Unit
Minimum setting
unit Panel/
Communication
Adjustment range
Default
setting
User
setting
Reference
H
0500 Acceleration time 2 s 0.1/0.1 0.1-3000 10.0 6.13
H
0501 Deceleration time 2 s 0.1/0.1 0.1-3000 10.0 6.13
H 0505 Acceleration/decelerat
ion 1 and 2 switching
frequency
Hz 0.1/0.01 0-WN 0.0 6.13
  Protection parameters
Title
Communication
No.
Function Unit
Minimum setting
unit Panel/
Communication
Adjustment range
Default
setting
User
setting
Reference
H 0601 Stall prevention level % 1/1 30-199 (%)
200 (disabled)
150 6.14.1
H
0602 Inverter trip retention
selection
--0: Not retained,
1: Retained
06.14.2
H 0603 External input trip stop
mode selection
--0:Coast stop
1:Slowdown stop
2:Emergency DC
braking
06.14.3
H 0605 Output phase failure
detection mode
selection
--0:Disabled
1:Selected (Output
open-phase is
checked when
operation is started
for the first time after
power is turned on.)
2:Selected (Output
open-phase is
checked each time
operation is started.)
06.14.4
H
0607 Motor 150%-overload
time limit
s1/1
10800
300 6.14.5
H
0608 Input phase failure
detection mode
selection
--0: Disabled,
1: Enabled
16.14.6
H 0616 Over-torque alarm
level
%10-200 150 6.14.7
H
0618 Over-torque detection
time
s0.10.0-10.0 0.5 6.14.7
H
0627 Under voltage trip
selection
--0:Disabled
1:Enabled (64% or
less: Trip, FL relay
activated)
2:Disabled (50% or
less: Trip, FL relay
not activated)
06.14.8
H
0633 Analog input
disconnection
detection
%10 (Disabled), 1 - 100% 0 6.14.9