Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ Portable Generator User Manual


 
TP-5695 12/93 Scheduled Maintenance 3-3
Service Schedule (Continued)
Before
Starting
After 20
Hrs. or
One
Month
Every 50
Hrs. or 3
Months
Every
100 Hrs.
or 6
Months
Every
200 Hrs.
or Yearly
Every
300 Hrs.
or 2 Years
ELECTRICAL SYSTEM
Check electrolyte level
(Batteries with filler caps only)
X X
Check and tighten electrical
connections
X
Check specific gravity
(Batteries with filler caps only)
X
Clean battery cables X
ENGINE AND MOUNTING
Check for leakage of water, fuel,
or oil
X X
Lubricate governor linkage
X (Break-in
Period)
X
Retighten all major nuts and
bolts
X (Break-in
Period)
X
Check and tighten mounting
bolts and vibromounts
X
Check intake/exhaust
valve clearance
X
REMOTE CONTROL SYSTEM,
ETC.
Check compartment condition
(fuel, oil, or water leaks)
X
Check the remote control
operation
X (Break-in
Period)
Test run generator set
X
(Monthly)
GENERATOR
Blow dust out of generator X