Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ Portable Generator User Manual


 
TP-5695 12/93 Specifications 1-1
Section 1. Specifications
Introduction
The craft is equipped with a dependable 110 volt
(reconnectable to 110/220 volt), 50 Hz; or 120 volt
(reconnectable to 120/240 volt), 60 Hz single-phase
alternating current marine generator set. Service
requirements are minimal but are very important to the
safe and efficient operation of the generator set;
therefore, inspect associated parts often. It is
recommended that an authorized service
dealer/distributor perform required servicing to assure
the unit continues to meet U.S.C.G. requirements.
Please take a few moments to read this manual, then
carefully follow all service recommendations to keep the
set in top condition. Keep this manual aboard the craft
for future reference. See Figure 1-1 for identification
and location of components.
Specifications
General Specifications
3.5CFZ 5CFZ
Dimensions--L x W x H--in. (mm) 27.87 x 17.50 x 16.60
(708 x 445 x 422)
31.07 x 18.10 x 17.50
(789 x 460 x 445)
with Sound Shield 31.07 x 18.10 x 17.50
(789 x 460 x 445)
31.07 x 18.10 x 17.50
(789 x 460 x 445)
Weight--(wet), lbs. (kg) 208 (94) 231 (104)
with Sound Shield 231 (104) 231 (104)
Air Requirements--cfm (L/min.) 18 (510) 18 (510)
Fuel Consumption U.S. gal./hr. (L/hr.)
Load
25% 0.42 (1.59) 0.44 (1.67)
50% 0.50 (1.89) 0.54 (2.04)
75% 0.59 (2.23) 0.66 (2.50)
100% 0.68 ( 2.57) 0.80 (3.03)
4CZ 6.5CZ
Dimensions--L x W x H --in. (mm) 27.87 x 17.50 x 16.60
(708 x 445 x 422)
31.07 x 18.10 x 17.50
(789 x 460 x 445)
with Sound Shield 31.07 x 18.10 x 17.50
(789 x 460 x 445)
31.07 x 18.10 x 17.50
(789 x 460 x 445)
Weight--(wet), lbs. (kg) 190 (86) 231 (104)
with Sound Shield 213 (96) 231 (104)
Air Requirements--cfm (L/min.) 18 (510) 18 (510)
Fuel Consumption U.S. gal./hr. (L/hr.)
Load
25% 0.48 (1.81) 0.53 (2.00)
50% 0.55 (2.08) 0.62 (2.34)
75% 0.62 (2.34) 0.86 (3.25)
100% 0.68 (2.57) 1.02 (3.86)