Rosemount Model 444 Alphaline Temperature Transmitters
5-8
ANALOG METER
SPECIFICATIONS
(OPTIONS B AND C)
Functional
Specifications
Meter Indication
0 to 100% linear scale.
Special optional ranges.
Temperature Limits
–40 to 65 °C (–40 to 150 °F).
Humidity Limits
0 to 100% relative humidity.
Zero Adjustment
Adjustment screw on face of meter.
Performance
Specifications
Indication Accuracy
±2% of calibrated span.
Temperature Effect
Less than 2% of full scale at any point within the temperature limits.
Physical
Specification
Meter Size
2¼-inch diameter face with 2-inch long scale.