Agilent Technologies HP8648A Weather Radio User Manual


 
RF Analyzer Specifications
262
RF Analyzer Specifications
RF Power Measurement
Standard
Frequency Range: 400 kHz to 1 GHz
Measurement Range:
1 mW to 60 W continuous
100 W for 10 seconds/minute (measured at RF IN/OUT connector)
Accuracy: ±10% of reading ±1 mW
SWR: <1.5:1
Resolution:
Power <10 W: 1 mW
Power 10 W: 10 mW
Option 007
Frequency Range: 400 kHz to 1 GHz
Measurement Range:
40µW to 2.4 W continuous
4.0 W for 10 seconds/minute
Accuracy: ±10% of reading ±40 µW
SWR: < 1.5:1
Resolution:
P < 400 mW: 40 µW
P 400 mW: 400µW
Option 008
Frequency Range: 400 kHz to 1 GHz
Measurement Range:
0.1 mW to 6 W continuous
10 W for 10 seconds/minute
Accuracy: ±10% of reading ±0.1 mW
SWR: < 1.5:1
Resolution:
P < 1 W: 0.1 mW
P 1 W: 1.0 mW