Xantrex Technology 120 VAC/60 Portable Generator User Manual


 
MENU SYSTEM
2001 Xantrex Technology, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
SW Series Inverter/Charger
Part No. 2031-5
Rev. C: February 2001
Page
35
SETUP MENU MAP
The SETUP MENU provides all the controls and settings needed when installing or adjusting the
system. To access the SETUP MENU, press both the red ON/OFF MENU and green GEN MENU buttons
on the Control Panel at the same time. To exit the SETUP MENU, press the red ON/OFF MENU button or
press the down MENU HEADING button until you reach the USER MENU (menu headings 1-8).
Inverter Setup
9
Battery Charging
10
AC Inputs
11
Gen Auto Start
setup 12
Gen starting
details 13
Auxiliary Relays
R9 R10 R11 14
Set Grid Usage
FLT SELL SLT LBX
Set Bulk
volts DC 14.4
Set Grid (AC1)
amps AC 60
Set Load Start
amp AC 20
Set RY7 Function
GlowStop Run
Set Relay 9
volts DC 14.5
Set Low battery
cut out VDC 11.0
Set Absorption
time h:m 02:00
Set Gen (AC2)
amps AC 30
Set Load Start
delay min 5.0
Set Gen warmup
seconds 60
R9 Hysteresis
volts DC 01.0
Set LBCO delay
minutes 10
Set Float
volts DC 13.4
Set Input lower
limit VAC 108
Set Load Stop
delay min 5.0
Set Pre Crank
seconds 10
Set Relay 10
volts DC 14.8
Set Low battery
cut in VDC 13.0
Set Equalize
volts DC 14.4
Set Input upper
limit VAC 132
Set 24 hr start
volts DC 12.3
Set Max Cranking
seconds 10
R10 Hysteresis
volts DC 01.0
Set High battery
cut out VDC 16.0
Set Equalize
time h:m 02:00
Set 2 hr start
volts DC 11.8
Set Post Crank
seconds 30
Set Relay 11
volts DC 15.0
Set search
watts 48
Set Max Charge
amps AC 20
Set 15 min start
volts DC 11.3
R11 Hysteresis
volts DC 01.0
Set search
spacing 59
Set Temp Comp
LeadAcid NiCad
Read LBCO 30 sec
start VDC 11.0
Close on batt >
setpoint.
Set Exercise
period days 30
Open on batt <
setpoint - Hys
Set Maximum run
time h:m 08:00
Relays have 2
second delay on
Set Max Run time
to 0 to defeat.
Close, 0.1 sec
delay on open
Set Exercise to 0
to defeat.
See menu 9 to
to set LBCO.
Bulk Charge
Trigger Timer 15
Low Battery
Transfer (LBX) 16
Battery Selling
17
Grid Usage Timer
18
Information file
battery 19
End Setup Menu
20
Set Start Bulk
time 00:00
Set Low Battery
TransferVDC 11.3
Set Battery Sell
volts DC 13.4
Start Charge
time 21:00
Batt temp comp
changes battery
To disable timer
set to 00:00
Set Low battery
cut in VDC 13.0
Set Max Sell
amps AC 30
End Charge
time 21:00
voltage reading
away from actual
If grid timer
active set bulk
See menu 9 to
enable LBX mode.
See menu 9 to
enable SELL mode.
After Start
Charge time:
HBCO resets at:
6v/48, 3v/24 and
time after start
charge time.
Make sure LBX is
above LBCO volts.
Make sure LBX is
above LBCO volts.
SELL mode
charges battery.
1.5v/12v under
HBCO.
In SLT mode dont
disable this
FLT mode
charges battery
LowBattTransfer
used in LBX, FLT
timer. It is the
daily chg time.
After End Charge
time:
Modes only. Goes
back to battery
SELL mode sells
battery to AC1.
at LowBattCutIn
(aka LBCI).
FLT mode drops
AC1 and inverts
For LBX mode set
below LBCI so
Timer on when
start < > end;
charger wont
cycle batteries
timer off when
start = end
up and down and
set LBCO below.
Sell and float
modes use timer
SLT and LBX mode
ignore timer
MENU HEADINGS
MENU ITEMS