Xantrex Technology 120 VAC/60 Portable Generator User Manual


 
MENU SYSTEM
Page
34
2001 Xantrex Technology, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
SW Series Inverter/Charger
Part No. 2031-5
Rev. C: February 2001
USER MENU MAP
Menu Heading
The values shown are the factory default values for
Model SW2512.
Menu Item
Setpoint
See the USER and SETUP menu item descriptions
for default values for other models.
Information
Inverter Mode
1
Generator Mode
2
Trace
Engineering 3
Meters
4
Error Causes
5
Time of Day
00:00:00 6
Set Inverter
OFF SRCH ON CHG
Set Generator
OFF AUTO ON EQ
Press reset now
for defaults
Inverter/charger
Amps AC 00
Over Current
NO
Set Clock hour
00:00:00
CHG avail. Only
in FLT mode.
Gen under/over
speed NO
Revision 4.01 Input amps AC
00
Transformer
overtemp NO
Set Clock minute
00:00:00
Press red or
setpoint button
Generator start
error NO
5916 195th St NE
Arlington, WA
Load
amps AC 00
Heatsink
overtemp NO
Set Clock second
00
to move.
Move cursor to
Generator sync
error NO
98223 USA Battery actual
volts DC 12.6
High Battery
voltage NO
Inverter OFF to
resetOverCurrent
Gen max run time
error NO
Ph 360-435-8826
Fax 360-435-2229
Battery TempComp
volts DC 12.6
Low Battery
voltage NO
Load Amp Start
Ready NO
Inverter
volts AC 00
Inverter breaker
tripped NO
Generator Timer
7
Voltage Start
Ready NO
Grid (AC1)
volts AC 00
AC source wired
to output NO
Start Quiet
Time h:m 08:00
Exercise Start
Ready NO
Generator (AC2)
volts AC 00
External error
(stacked) NO
End Quiet
Time h:m 08:00
Move cursor to
GEN OFF to reset
Read Frequency
Hertz 60
Generator start
error NO
Gen doesn’t run
During quiet
Generator error. AC1 & AC2 volts
valid only when
Generator sync
error NO
time unless batt
volts is less.
If no start in 5
trys then error.
inverter synced
to that input.
Gen max run time
error NO
than LBCO volts
for 30 seconds.
If Gen starts &
runs for 5 min
Batt volt actual
is used for
Gen under/over
speed NO
To defeat timers
set start = end.
then stops the
inverter will
LBCO,HBCO,LBX,
LBCI,sell volts,
Inverter breaker
tripped NO
If exercise day
set to 1 then
not attempt
restart until
and gen starting gen will always
start @ endquiet
gen auto start
conditions are
Batt volt temp
comp is used,
again satisfied. for float, bulk, eq
& aux relays
If Gen runs for
More than max
Run time then
Error.
Under/Over speed
Will cause a
Sync error in 10
minutes
End User Menu
8
MENU HEADINGS
MENU ITEMS
Push buttons on
Control Panel