Syntax and Commands
3-60 AFG3000 Series Arbitrary/Function Generators Reference Manual
EFILe
EFILe is specified as an output waveform.
Returns
SIN|SQU|PULS|RAMP|PRN|DC|SINC|GAUS|LOR|ERIS|EDEC|HARV|USER1|USER2
|USER3|USER4|EMEMory|EFILe
Examples
SOURce1:FUNCtion:SHAPe SQUare
selects the shape of CH 1 output waveform to square waveform.
[SOURce[1|2]]:PHASe[:ADJust]
This command sets or queries the phase of output waveform for the specified
channel. You can set the value in radians or degrees. If no units are specified, the
default is RAD. The query command returns the value in RAD.
This command is supported when you select a waveform other than DC, Noise, and
Pulse.
Group
Source
Syntax
[SOURce[1|2]]:PHASe[:ADJust] {<phase>|MINimum|MAXimum}
[SOURce[1|2]]:PHASe[:ADJust]? {MINimum|MAXimum}
Arguments
<phase>::=<NR3>[<units>]
where
<NR3> is the phase of output frequency.
<units>::=[RAD | DEG]
If <units> are omitted, RAD is specified automatically. The setting ranges are:
RAD –1 PI to +1 PI, relative to phase value
DEG –180 to +180, in 1 degree steps, relative to phase value
Returns
<phase>
Examples
SOURce1:PHASe:ADJust MAXimum
sets the maximum value for the phase of CH 1 output frequency.