2-2
LS 3070 Product Reference Guide: Setup
The RL 470 base station is a charger, host interface, and — significantly —
receiving station for RF transmission. Therefore, do not install the RL 470
inaccessibly under a table or buried in a desk drawer. At a minimum, mount
the RL 470 on a table or desk top. For optimum RF performance, especially in
difficult environments, mount the RL 470 on a wall as high as possible. But
keep in mind the limits of interface cable length and charging accessibility.
Proper base positioning gives you the best possible range and coverage
performance from the LS 3070 cordless scanning system.
Inserting the Scanner Into and Removing
Scanner from Base/Charger
To insert the scanner into the base/charger:
1. First, place the nose to the scanner into the large rectangular receptacle of
the base/charger.
2. Then place the scanner handle into the opening of the smaller, latched
receptacle and press down firmly until the bottom of the handle seats
snugly into the receptacle and engages the latch.
Caution
Use of excessive force in placing the scanner into the base can
damage the charging contacts on the shoe of the scanner or in the
receptacle of the base. Such damage can interfere with or prevent
charging of the scanner’s batteries by the base
.
3. To remove the scanner from the base/charger, grasp the handle of the
scanner and lift the bottom of the handle out of the latched receptacle,
thereby freeing the scanner from the base.
Caution
It is important to remove the scanner
handle-first
. Trying to re-
move the scanner nose-first can break latch in the base receptacle
.