REPORT CONSOLE TROUBLE
The factory setting does not report Console
trouble events to the Central Station.
Alternately, the communicator can be
programmed to report Console trouble events.
These include all conditions that light the
Console’s BATTERIES or TROUBLE indicator. It
also includes low Console backup battery.
REPORT FORCE ARMING
The factory setting does not send force arming
reports.
Alternately, the communicator can be
programmed to report force arming anytime the
Console is armed with one or more bypassed
sensors.
The factory set reporting code for force arming is
“65” (Code 574 with Ademco).
NOTE: If force arming is enabled, and the Console
is force armed (armed with an open sensor)
remotely by telephone, or with the RA-2400
Remote Access software, the caller will be
disconnected if the communicator is enabled.
OPENING AND CLOSING REPORTS
The factory setting does not send opening and
closing reports
Alternately, the communicator can be
programmed to send an opening report when the
system is disarmed, and a closing report when
the system is armed for all users, or just the
master user.
NOTE 1: For commercial installations using
opening and closing reports, it is recommended to
disable quick arming to prevent customers from
arming the system.
NOTE 2: The reporting codes are fixed for opening
and closing. A unique code is reserved for the
master user code and each of the five restricted
user codes.
NOTE 3: Arming or disarming with the page alert
user code dials the supervisory number, no
opening or closing report is sent.
POINT ID REPORTING
The factory setting enables Point ID and allows
the communicator to send two-digit alarm and
trouble codes for each sensor. The individual
sensor that causes an alarm or trouble report can
be identified at the Central Station.
Alternately, Point ID can be disabled. The Central
Station will only receive general alarm and
trouble reports.
0 FOR NO CONSOLE TROUBLE
1 FOR CONSOLE TROUBLE
PROGRAMMING STEP #108
PROGRAM
STORE PROGRAM
0 FOR NO FORCE ARMING RPTS.
1 FOR FORCE ARMING RPTS.
PROGRAMMING STEP #110
PROGRAM
STORE PROGRAM
0 FOR GENERAL REPORTS ONLY
1 FOR POINT ID REPORTING
PROGRAMMING STEP #113
PROGRAM
STORE PROGRAM
0 FOR NO OPEN/CLOSE REPORTS
1 FOR O/C RPTS. FOR ALL USERS
2 FOR O/C RPTS. FROM MASTER
USER ONLY
PROGRAMMING STEP #111
PROGRAM
STORE PROGRAM
37