CALL LIMITER
The factory setting for the call limiter is OFF.
This allows the communicator to report burglary
alarms, once for each sensor, as many times as
they are triggered.
Optionally, the Console can be programmed to
only allow five burglary reports total per arming
period.
NOTE: Sensors programmed to 24-hour functions
(Emergency, Panic, Fire) always send a Central
Station Report and always sound the local siren
regardless of the Call Limiter setting.
DIALING DELAY
The factory setting will cause the communicator
to dial the Central Station instantly when an
alarm or supervisory event occurs.
Alternately, the communicator can be
programmed to wait 30 seconds before dialing.
This gives the user time to disarm the system
and prevent communications in the case of a
subscriber generated false alarm.
DIALING METHOD
The factory setting causes the communicator to
dial using DTMF (dual-tone multi-frequency)
tone dialing.
Alternately, the communicator can be
programmed to use pulse (rotary) dialing. Use
this option if the telephone line in the installation
does not support tone dialing.
0
1
HOME
AWAY
0 FOR OFF (UNLIMITED)
1 FOR ON (5 VIOLATIONS)
PROGRAMMING STEP #101
PROGRAM
STORE PROGRAM
1
0 FOR NO DELAY
1 FOR 30 SECOND DELAY
PROGRAMMING STEP #103
PROGRAM
STORE PROGRAM
0
4
GHI
HOME
AWAY
0 FOR TONE DIALING
1 FOR PULSE DAILING
PROGRAMMING STEP #104
PROGRAM
STORE PROGRAM
1