PROGRAMMING DIFFERENT SENSOR TYPES
Follow the instructions on the previous page to
select a sensor number to program the sensor
into.
NOTE: A sensor can be programmed into more
than one location. Be sure to choose an unused
sensor number. If a sensor gets entered into more
than one location, delete the duplicates using the
remove sensor function.
To add DXS-10 wireless keypads,
press and
hold the keypad’s [
] key until programmed into
the Console.
IMPORTANT NOTE: The DXS-31 & DXS-32
door/window sensors are pre-set at the factory for
delayed burglary response. If the sensor is going
to be used on a non-entry portal (window, sliding
glass door, etc.) a jumper can be changed in the
sensor to select instant response. The jumper
should be changed before learning the sensor so the
Console will program the sensor to the proper
function. See the “Basic Sensor Installation” section
of this manual for details on changing the jumper.
For DXS-31 and DXS-32 door/window sensors,
move the magnet away from the side of the
sensor.
For DXS-81, DXS-91, DXS-54, & DXS-72
accessory sensors, simply send a test
transmission (refer to the sensor’s instructions
for details on sending a test transmission).
For DXT-61, DXT-21, DXS-21 & DXT-41
single-button remotes, simply press the unit’s
button. The unit will function as an arm/disarm
remote.
NOTE: After the Console “learns” the transmitter,
single-button remotes can easily be
re-programmed as “panic buttons” or home
automation controllers. Refer to Page 24 in the
“Customizing the System” section of this manual.
For DXT-23 & DXT-42 multi-button remotes: Learn
the transmitter by pressing the left button. The
remote will arm the Console with the left button and
disarm with the right. Labels are provided with the
DXT-42 for identifying the buttons.
NOTE: After the Console “learns” the transmitter,
multi-button remotes can easily be re-programmed
to have the left button arm/disarm the Console and
the right button activate/deactivate the Home
Automation Output. Refer to Page 24 in the
“Customizing the System” section of this manual.
A single “bing” tone will sound and the sensor
status indicator will stay lit when the sensor is
learned by the Console.
A double “buzz” tone will sound if there is
already another sensor programmed to that
sensor number.
Exit Setup Mode by holding the [
OFF
] button for
two seconds. Reminder: The Console will
automatically exit the Setup Mode and return to
Off Mode after 3 minutes of keypad inactivity.
NOTE: To remove sensors from the Console’s
memory, see Page 22 in the “Customizing the
System” section of this manual.
SEND SIGNAL WITH LEFT BUTTON
LEFT = ARM
RIGHT = DISARM
BOTH = EMERGENCY