Linear DVS-2400 Pressure Washer User Manual


 
Black 0034
Black0034
13. COMMUNICATOR PROGRAMMING
SETUP MODE
To perform any of the communicator
programming steps, the Console must be in the
Setup Mode.
Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press the [
HOME
] key (HOME = program), enter
the new value, and press the [
AWAY
] key
(AWAY = store). Follow the figures next to the
programming step.
Start with the Console in Test Mode (Setup Mode
cannot be reached from any other mode).
From Test Mode, enter the master user code
then press [
TEST
].
NOTE: Only the master user code can be used to
put the Console into the Setup Mode. The
restricted user codes cannot access Setup Mode.
A “gong” and five “beeps” will sound, signaling
that the Console is in Setup Mode.
Hold the [
OFF
] key for three seconds when you
want to exit Setup Mode.
NOTE: If the Console is left unattended in Setup
Mode, it will automatically switch back to Off Mode
after three minutes.
GENERAL COMMUNICATOR OPTIONS
STEP #
PROGRAMMING
FUNCTION
POSSIBLE
VALUES
FACTORY
VALUE
INSTALLATION
VALUE
76 2-WAY AUDIO 0 = NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX 0
78
VOICE RESPONSE FROM CONSOLE SPEAKER
(AND REMOTE SPEAKER IF USED)
0 = VOICE RESPONSE DISABLED
1 = VOICE RESPONSE ENABLED
0
100 REMOTE PROGRAMMING LOCKOUT 0 = UNLOCK; 1 = LOCK 0
101 CALL LIMITER 0 = OFF; 1 = FIVE CALLS PER ARMING PERIOD 0
103 DIALING DELAY 0 = NO DELAY; 1 = 30 SECOND DELAY 0
104 DIALING METHOD 0 = TONE; 1 = PULSE 0
107 COMMUNICATOR ENABLE 0 = COMMUNICATOR OFF, 1 = COMMUNICATOR ON 0
General Communicator Programming Table
START IN TEST
MASTER
USER
CODE
1 GONG &
5 BEEPS
TEST
SETUP MODE
32