Linear DVS-2400 Pressure Washer User Manual


 
Black 0035
Black0035
GENERAL COMMUNICATOR OPTIONS
COMMUNICATOR ENABLE
The factory setting for the Console disables the
communicator. If the system is going to be a
non-monitored, local alarm only, leave the
communicator disabled.
If the system is going to be monitored by a
Central Station, enable the communicator with
this programming step.
2-WAY AUDIO
When the Model VB-2 voice module is installed,
the communicator can provide 2-way audio
capability.
The audio module can be programmed for listen
only, 2-way manual operation (using a
pushbutton telephone at the Central Station),
and 2-way full duplex hands free operation.
Refer to the VB-2 installation instructions for
details on operating the audio module.
NOTE: The Model VB-2 Digital Voice Synthesis
module must be installed for this option to
function.
The factory setting for the VB-2 audio module is
OFF.
Alternately, the audio module can be set for (1)
listen-only, (2) 2-way manual, (3) 2-way full
duplex.
NOTE: Units programmed for two-way duplex can
still be controlled manually by pressing the “1" or
”3" key. In addition, the Central Station can return
the unit to two-way duplex by pressing the “8" key.
VOICE RESPONSE
The Console can be programmed to allow its
speaker to play audio produced by the VB-2 or
VB-3 digital voice synthesis modules.
This selection can also be used when a remote
speaker is connected to the Console.
The factory setting is to disable the Console’s
speaker from playing voice module audio.
Alternately, the Console can be programmed to
enable voice module audio.
NOTE: Turning voice response OFF with this
programming step will only effect the audio
produced by the voice module. It will not stop the
Console’s speaker from sounding local sirens and
tones.
NOTE: A Model VB-2 or VB-3 Digital Voice
Synthesis module must be installed for this option
to function.
REMOTE LOCKOUT
The factory setting for the communicator is to
allow remote connection to the Console with
Linear’s RA-2400 Remote Access Software and
a modem (unlocked).
Alternately, the Console can be programmed to
not answer incoming calls, thereby, not allowing
remote access (locked).
0
7
PRS
HOME
AWAY
0 FOR COMMUNICATOR OFF
1 FOR COMMUNICATOR ON
PROGRAMMING STEP #107
PROGRAM
STORE PROGRAM
1
7
PRS
6
MNO
HOME
AWAY
0 FOR NO AUDIO MONITORING
1 FOR LISTEN-ONLY
2 FOR 2-WAY MANUAL
3 FOR 2-WAY FULL DUPLEX
PROGRAM
STORE PROGRAM
PROGRAMMING STEP #76
7
PRS
8
TUV
HOME
AWAY
0 FOR NO VOICE RESPONSE
1 FOR VOICE RESPONSE
PROGRAMMING STEP #78
PROGRAM
STORE PROGRAM
0
0
HOME
AWAY
0 FOR UNLOCK
1 FOR LOCK
PROGRAMMING STEP #100
PROGRAM
STORE PROGRAM
1
33