Linear DVS-2400 Pressure Washer User Manual


 
Black 0011
Black0011
EXTERNAL CONSOLE SPEAKER CONNECTION (OPTIONAL)
An external console speaker sounds system
tones and alerts occupants with a loud siren
during alarm.
With the VB-2 module installed, the Central
Station can talk to the occupants through the
external console speaker.
Use an 8-ohm, 10 watt minimum rated speaker.
Do not use a horn/siren with a built-in siren
driver.
Up to two 8-ohm speakers can be used with
each Console.
Up to 150 feet of 22 AWG wire can be used with
each speaker.
Mount the external speaker.
Route the speaker wires from the external
speaker to the Console.
Open the Console top cover and locate the main
terminal block.
Route the speaker wires up through the wiring
access hole.
Remove the wire jumper from the EXT. SPKR &
(-) terminals.
Connect the speaker wires to the EXT. SPKR &
(-) terminals.
NOTE: If connecting two external speakers,
connect the second speaker in parallel, to the
same EXT. SPKR & (-) terminals as the first
speaker.
The system tone volume can be adjusted with
the annunciator volume control.
EXTERNAL ALARM SIREN CONNECTION (OPTIONAL)
An external siren alerts occupants and neighbors
with a loud siren during alarm.
Use a 12 volt, 1 amp maximum rated
weather-resistant horn speaker with a built-in
siren driver. Do not use a plain speaker.
NOTE: Connection of an electromechanical bell or
motor bell is not recommended because of the
radio interference generated when the bell is
running.
Mount the external siren.
Route the wires from the external siren to the
Console.
Open the Console top cover and locate the main
terminal strip.
Route the siren wires up through the wiring
access hole.
Connect the siren wires to the RELAY N.O. & (-)
terminals.
NOTE: By removing the Console’s auxiliary fuse,
the relay contacts will become isolated. Use the
RELAY N.O. & RELAY DRY terminals to switch an
externally powered load.
EXTERNAL
CONSOLE
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
MAIN TERMINAL BLOCK
EXT. SPKR(S)
8 OHM/10 WATT
2 SPKRS MAX.
NOTE: REMOVE
JUMPER FOR
EXT. SPEAKERS
OPTIONAL
VOICE MODULE
MODEL: VB-2 OR VB-3
MAIN
TERMINAL
BLOCK
ANNUNCIATOR
VOLUME
CONTROL
LINEAR SECURITY CONSOLE MODEL DVS-2400
CONNECT SPEAKER LEADS
TO EXT. SPKR & (-) TERMINALS
REMOVE
JUMPER
EXTERNAL
CONSOLE
SPEAKER
8 OHM, 10 WATT
MINIMUM
CONNECT SIREN LEADS TO
(-) & RELAY N.O. TERMINALS
EXTERNAL
ALARM RELAY
12 VDC 1 AMP
MAXIMUM
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
MAIN TERMINAL BLOCK
EXTERNAL SIREN
12 VDC 1 AMP
MAXIMUM
OPTIONAL
VOICE MODULE
MODEL: VB-2 OR VB-3
MAIN
TERMINAL
BLOCK
LINEAR SECURITY CONSOLE MODEL DVS-2400
EXTERNAL
ALARM
9