Linear DVS-2400 Pressure Washer User Manual


 
Black 0017
Black0017
DXS-31 & DXS-32 DOOR/WINDOW SENSORS
The DXS-31 and DXS-32 sensors can be used to
monitor doors, windows, cabinets, crawl space
doors, gates, freezer doors, and many other
moving objects that could be used for intrusion
or need to be monitored.
A built-in magnetic switch triggers the sensor
when its magnet (mounted on the moving part
or the door or window) moves away from the
sensor.
External normally closed switches (DXS-31
only) can be wired to the sensor for remote
triggering.
The door/window sensor (DXS-31 only) can
connect directly to a glass break detector.
SET SENSOR JUMPER
A jumper inside the door/window sensor selects
instant or delayed response.
If the sensor is going to be used on the primary
entry/exit door make sure that the jumper is in
the DELAY position.
If the sensor is going to be used on a window or
a door that is not going to be used to enter and
exit the premises, set the jumper to the
INSTANT position.
APPLY DOUBLE-STICK TAPE
Apply double-stick tape (supplied) to back of
sensors and magnets.
Screws are also provided to mount sensors and
magnets.
Screws are preferred over the double-stick tape
in permanent installations.
ATTACH SENSORS AND MAGNETS
On doors, mount sensor to door frame and
magnet to door.
NOTE: Magnet must line up with mark on sensor
case both horizontally & vertically.
Allow a maximum of 1/2" between magnet and
sensor when door/window is closed.
Snap sensor onto mounting plate.
On windows, mount sensor to window frame and
magnet to window.
Snap sensor onto mounting plate.
The magnet height is adjustable and an optional
magnet spacer is provided for uneven surfaces.
TEST SENSORS
Console in Chime Mode should “ding-dong”
when the sensor sends signal.
Open door or window.
Verify that light on the sensor glows momentarily
when door/window is opened.
Status indicator on Console should remain lit for
each door/window sensor that is left open.
TRANSMITTER
MOUNTED ON
DOOR JAMB
(NOTE: SMALL END
OF TRANSMITTER UP)
(NOTE: SMALL END
OF TRANSMITTER DOWN)
MAGNET
MOUNTED
ON DOOR
MAGNET MOUNTED
ON DOOR
TRANSMITTER
MOUNTED ON
WINDOW SILL
MAGNET MOUNTED
ON WINDOW FRAME
SLIDING WINDOW
LEFT OPENING DOOR
RIGHT OPENING DOOR
TRANSMITTER
MOUNTED ON
DOOR JAMB
TRANSMITTER
MOUNTED ON
WINDOW FRAME
MAGNET
MOUNTED
ON WINDOW
SASH STILE
DOUBLE-HUNG
WINDOW
EXAMPLE INSTALLATIONS
(WITH DXS-31 SHOWN)
TRANSMIT
INDICATOR
INPUT
SELECT
JUMPER
INSTANT/DELAY
OPTION JUMPER
ANTENNA
MAGNET
ALIGNMENT
MARK
TWO TYPE 2032
BATTERIES
BATTERY CLAMP
EXTERNAL
INPUT
TERMINALS
TEST
SWITCH
BATTERY
CLAMP
SCREW
INSTANT/DELAY
OPTION JUMPER
SELECTS
DELAY
SELECTS
INSTANT
ATTACH MOUNTING PLATES
USING THE SCREWS OR
DOUBLE-STICK TAPE PROVIDED
NOTE: ATTACHING THE TRANSMITTER WITH DOUBLE-STICK
TAPE IS NOT ALLOWED IN UL INSTALLATIONS
1. PLACE RECEIVER INTO
PROGRAM OR "LEARN" MODE
2. ACTIVATE TRANSMITTER
BY OPENING DOOR OR
WINDOW
3. VERIFY THAT THE
RECEIVER ACCEPTED THE
SIGNAL
4. REPLACE TRANSMITTER
COVER WHEN FINISHED
NOTE: THE TRANSMIT
INDICATOR WILL ONLY LIGHT
DURING TRANSMISSIONS
WHEN THE CASE IS OPEN
(EXCEPT WHEN PUSHING
THE CASE FOR TESTING)
OPEN DOOR, TRANSMIT
INDICATOR SHOULD LIGHT
15