7) ELECTRICAL SUPPLY: The electrical supply for this spa must
include a suitably rated switch or circuit breaker to open all
u n g rounded supply conductors to comply with section 680-42 of the
National Electrical Code, ANSI/NFPA 70-1993. The disconnect must
be readily accessible and visible to the spa occupant but installed at
least 5 feet (1.5 m), from the spa water.
8) WARNING: To Reduce the Risk of Injury:
a) The water in a spa should never exceed 104° F (40° C). Water
temperatures between 100° F (38° C) and 104° F (40° C) are
considered safe for a healthy adult. Lower water temperatures are
recommended for young children and when spa use exceeds 10
minutes.
b) Since excessive water temperatures have a high potential for
causing fetal damage during the early months of pregnancy,
pregnant or possibly pregnant women should limit spa water
temperatures to 100° F (38° C).
c) Before entering a spa, the user should measure the water
temperature with an accurate thermometer since the tolerance of
water temperature-regulating devices may vary as much as +/- 5°
F (2° C).
d) The use of alcohol, drugs, or medication before or during spa use
may lead to unconsciousness with the possibility of drowning.
e) Persons suffering from obesity or with a medical history of heart
disease, low or high blood pressure, circulatory system problems,
or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using
a spa since some medication may induce drowsiness, while other
medication may affect heart rate, blood pressure, and circulation.
IMPORTANT SAFETY INSTRUCTIONS
(CSA SAFETY INFORMATION)
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
a) READ AND FOLLOW ALL INSTRUCTIONS.
b) A green coloured terminal or a terminal marked G, GR, Ground,