25
2000 Owner’s Manual
7) When the jets are in full operation, close the bleeder valve and push
the UP pad until the desired spa temperature is indicated on the dis-
play screen. (The maximum settable temperature is 104˚, OR5 or
OR6.) The screen will then read 100˚ F for thirty seconds to allow
the thermostat time to read the correct current water temperature.
Then, the screen will display the current spa water temperature.
NOTE: While setting the temperature, the LCD display will read out
the temperature up to 104˚ F. When the temperature exceeds 104˚ F, the
display will read in “over-range” figures. I.E. at 105˚ F the temperature
will read “OR5” and at 106˚ F the temperature will read “OR6”. Water
temperatures in excess of 104˚ F should be used with extreme cau -
tion.
NOTE: On initial start-up, you can confirm that the heater is on by
looking to see that the heat LED indicator located on the right side of
the spa control panel is illuminated. A scrolling message will also appear
on the lower line of the LCD reading SPA HEATING TO _ _ _˚ F
(whatever the set temperature is) as well as an animated icon on the
LCD. Once you have verified that the heater is functioning, you can
reinstall the ventilated equipment access panel.
N O T E : Depending upon the size of the spa and the size of the circ u i t
b reaker used, heating will occur at the rate of 3-10˚ F per hour.
8) After completing the above steps, it is necessary to ensure proper
water chemistry. See the Water Chemistry section in this manual,
for the easy steps to maintaining clean and safe water. The schedule
shown may require more frequent adjustment depending on the
bather load.
9) Place the thermal cover on the spa to conserve energy and to keep it
ready for use.