15
2000 Owner’s Manual
ELECTRICAL REQUIREMENT CHART
To hook-up your spa, follow these instructions:
Model Branch Cir . Gauge
C h a i rman II 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
D i p l o m a t 2 4 0 V, 38A 3 Wi r e + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
C h a i rm a n 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
C a l i f o rn i a n 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
N a u t i l u s 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
A u rora II 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 32A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
Triad II 2 4 0 V, 30A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
A u rora HP 2 4 0 V, 38A 3 Wi re + gro u n d 5 0 A #6 AW G
2 4 0 V, 30A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
I n t e r l u d e 2 4 0 V, 30A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
A re n a 2 4 0 V, 30A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
Tr i a d 2 4 0 V, 30A 3 Wi re + gro u n d 4 0 A #6 AW G
2 4 0 V, 24A 3 Wi re + gro u n d 3 0 A #8 AW G
Branch Cir .
Protection
Electrical
Rating