Dimension One Spas 2000 Model Hot Tub User Manual


 
36
2000 Owner’s Manual
Maintaining proper water chemistry is imperative to maintaining safe
water and preventing possible damage to your spa components.
START-UP PROCEDURES:
NOTE: If using Vision systems, disregard the steps listed below and fol-
low the start-up procedures in the instructions located in the box with
the Vision cartridge.
1) Add stain and scale control, or a sequestrant.
2) Test and adjust Total Alkalinity. Run the pump for 1 hour at high
speed.
3) Test and adjust pH. Run the pump for 1 hour at high speed.
4) Add Sanitizer:
a) Add 2oz. packet of Bromo Shock
OR
b) Add 2oz. packet of Chlorine
5) Fill and set Adjustable Bromine Feeder and place it in the weir skim-
mer basket.
6) On the following day, shock water with shock treatment with jets
running. (Wait at least 20 minutes before entering the spa.)
7) Add enzyme remover (you may wish to add clarifier the following
day, as the introduction of sequestrant with enzyme remover may
temporarily cloud the water).
8) Run the pump for 1 hour at high speed.
WATER QUALITY
Your Dimension One spa is equipped with a cartridge filter system.
Filtering the water helps maintain water cleanliness and clarity. While
the filter traps most solid materials, it is still necessary to add a sanitizer
such as chlorine or bromine to the water in order to control bacteria,
algae, and to oxidize any organic materials in the water.
WATER CHEMISTR Y