30 www.seektech.com Ridge Tool Company Elyria, Ohio U.S.A
SeekTech SR-60
11. Display Elements Control (Sub-
menus will display when selected for Sonde
or line tracing modes.)
12.
Frequency Selection Control
(Sub-menus will display for categories of
frequencies that can be selected.)
13.
Information Menu including software
version and unit serial number (sub-menu for
restoring factory defaults will display on
Information screen).
See the Menu Tree on page
35 for a complete list.
SimulTrace Mode
The SimulTrace mode is off by default and can be
activated by selecting it in the Frequency Selection
Control sub-menu. It provides simultaneous tracing of
a 512 Hz Sonde and a 33 kHz line for easier tracking
of underground pipes using a Sonde.
Currently Available Sonde Frequencies
Frequencies that have been set to “Checked-Active”
status appear with a check box next to them. If the
checkbox is checked, the frequency can be accessed
using the Frequency Key
. Frequencies are
checked or unchecked by highlighting them and
pressing the Select Key. To return to the operating
screen, press the Menu Key.
See the Frequency List on page
9.
Currently Available Active Line Trace
Frequencies
Frequencies that have been set to “Checked-Active”
status appear with a check box next to them. If the
checkbox is checked, the frequency will be activated
and can then be accessed using the Frequency Key
. Frequencies are checked or unchecked by
highlighting them and pressing the Select Key. To
return to the operating screen, press the Menu Key.
See the Frequency List on page
9.
Currently Available Passive Line Trace
Frequencies
As with other frequency categories, these items will
appear in the “Checked-Active” set when checked.
See the Frequency List on page
9.
Currently Available Radio Frequencies
As with other frequency categories, these items will
appear in the “Checked-Active” set when checked.
See the Frequency List on page
9.
OmniSeek Mode
The OmniSeek mode allows simultaneous tracing in
multiple high-frequency bands: <4 kHz, 4-15 kHz, and
15-35 kHz.
Change of Depth Units
The SR-60 can display Measured Depth in either Feet or
Meters (
Figure 48). Feet are shown in feet-and-inches
format; meters are in decimal format. To change these
settings, highlight the Depth Units selection in the menu
and press the Select Key to toggle between feet or
meters. Use the Menu Key to save the section and exit.
Figure 48: Selecting Units (Feet/Meters)
Back Light Control
A light detector built into the upper left corner of the
keypad senses low light levels. The backlight can be
forced on by blocking the light to this sensor.
The automatic LCD backlight is factory set to only switch
on under fairly dark conditions. This is to conserve
battery power. As the batteries near depletion, the
backlight will appear dim.
To set the backlight to be always off, highlight the light
bulb icon in the tools section of the menu. Press the
Select Key to toggle it between Auto, always ON and
always OFF.