Cal Spas LTR20051000 Hot Tub User Manual


 
Appendix
Page 70 2005 Spa Owner's Manual
8/1/2005
Configuration Settings
When DIP switch A10 is turned ON while the spa is powered up and running, the system will enter the Edit
menu for configuration settings.
Press any temperature button to scroll through the list of settings shown in the table below.
Pres JETS 1 on the main control panel to select a feature. The configuration setting will flash.
Press any temperature button to scroll through the various configuration settings for the feature.
Pres JETS 1 to select a configuration and return to the feature list.
Pres TEMP to continue scrolling through the list.
Continue until all settings are chosen.
Turn DIP switch A10 to the OFF (down) position.
The spa will automatically reset and begin to run with the new settings.
Do NOT start up the spa with A10 turn on or the CFE error will occur. CFE errors are illegal
configurations such as a pump blower set to run on the same output. The configuration must be corrected
before the spa will operate.
Message Message Description Settings
Three
pump
system
Five
pump
system
Two
pump
system
with
TV
F 1
Pump 1 in filter (w/circulation
pump
N Y
Allows P1 low to operate in filter cycles to add extra
filtration
N = normal; Y = Pump 1 with Circ
N N N
24
24-hour time
N Y
N = 12-hour (am/pm); Y = 24-hour (military)
N N N
t c
Celsius
N Y
N = Fahrenheit; Y = Celsius
N N N
t o
Timeouts
1 F 2 3 4 5 6
1-6 = 10, 20, 30, 40, 50, 60 minutes; F = 15 minutes
F F F
1 t
Pump 1 low timeout
d 1 2 3 4
d = Use “Timeouts” value above; 1-4 = number of
hours
2 2 2
L t
Light timeout
d 1 2 3 4
d = Use “Timeouts” value above; 1-4 = number of
hours
4 4 4
S c
Scrunch Panel
N Y
N = Normal button positions on ML900; Y = Scrunch
N N N
c t
Circ Type
N A 3 P
N = Non circ; A = 24-hour; 3 = 24-hour w/3°F shutoff
outside filter; P = Acts like Pump 1 Low (filter cycles,
polls, etc.)
P P N or P
P 1
Pump 1 Speeds
1 2
1 = 1 speed; 2 = 2 speed
2 1 2
P 2
Pump 2 Speeds
0 1 2
0 = Disabled; 1 = 1 speed; 2 = 2 speed
2 1 2
P 3
Pump 3 Speeds
0 1 2
0 = Disabled; 1 = 1 speed; 2 = 2 speed
2 1 0
P 4
Pump 4 Speeds
0 1 E
0 = Disabled; 1 = 1 speed; E = On/Off via External
Relay
0 1 0