Cal Spas LTR20051000 Hot Tub User Manual


 
Operating Your Spa
2005 Spa Owner's Manual Page 33
8/1/2005
Locking the Panel
To lock the panel:
Press TIME, JETS 1, and the UP button within three seconds. When locked, the panel will display “LOCK”.
All buttons are frozen except the TIME button.
To unlock the panel:
Press TIME, JETS ,1 then the DOWN button within three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the UP or DOWN button, TIME, JETS 1, then the UP button within three seconds. The panel will
display “TEMP LOCK” when the set temperature is locked.
To unlock the set temperature:
Press the UP or DOWN button, TIME, JETS 1, then the DOWN button..
Circulation Pump
This is an optional feature. The circulation pump will come on when the system is checking temperature, during
filter cycles, during freeze conditions, or when another pump is on.
Preset Filter Cycles
There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the
time as instructed above, then press MODE/PROG to advance to the next setting (or to exit after the last
setting). The default filter cycles are as follows:
The first filter cycle is automatically activated at 8:00 AM and operates the pump until 10:00 AM. The
“FILTER 1” indicator icon will light when filter 1 is running.
The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM. The
“FILTER 2” indicator icon will light when filter 2 is running.
The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run
on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run
for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to
run according to your desired programming.
Clean-up Cycle
When the pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or
blower is turned off or times out. The pump and the ozone generator will run for one hour.
Ozone
This is an optional feature. On most systems, the ozone generator (if installed) runs during filter cycles (except
when pump 1 is operating at high speed on a non-circ system) and during clean-up cycles. On some systems,
the ozone generator operates whenever the pump runs. If your system is configured with the optional ozone
disable feature, the ozone generator will turn off for one hour any time a function button (JETS 1, JETS 2,
OPTION etc.) is pressed.