Cal Spas LTR20051000 Hot Tub User Manual


 
Operating Your Spa
After selecting the desired filtration cycle duration, press the Jets pad to exit the filtration program. The
circulating pump and ozone generator (optional) will run during filtration cycles.
NOTE: The filtration cycle settings of F8 and FC are only intended for use with the optional Spa Cal™
Filtration System.
Safety Suction System
Your new Cal Spa is equipped with a state-of-the-art Safety Suction System. This will automatically shutdown
the spa in the event of a filtration or suction restriction, and display SF on the topside control panel. If this
happens, check all suction fittings and filter cartridge(s) for obstructions. Then, reset the system by pressing any
control panel button.
Diagnostic Messages
Message Meaning
OH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! If the spa has
reached 112˚F (45˚C), remove the spa cover to cool the water. Overheating may occur if
the filter cycle is set too long. At 110˚F (43˚C), the spa should reset itself. If the high-
limit sensor detects 118˚F (48˚C) at the heater, the spa will shut down. When the heater
cools down to 110˚F (43˚C), press any button to reset the spa. If the spa will not reset,
then shut the power off to the spa and call your dealer of service organization.
FL Flow Detection Switch. Pressure switch is not working correctly. Call your dealer or
service organization.
Sn Sensor (Spa is shut down). The high limit or water temperature sensor is not working
correctly. Call your dealer or service organization.
Sf Vacuum Switch (Spa is shut down). The display will show “SF” as soon as the vacuum
switch closes. All functions will turn off and the system will be disabled until a panel
button is pressed.
LED Heater LED will come on when the heater is on (and goes off when heater is off).
Ozone LED will come on when in filtration cycles.
Safety switch is a status LED noting power and system monitoring.