Agilent Technologies 66311B Portable Generator User Manual


 
8 – Language Dictionary
106
MEASure:CURRent?
FETCh:CURRent?
These queries return the dc output current.
Query Syntax
MEASure[:SCALar]:CURRent[:DC]?
FETCh[:SCALar]:CURRent[:DC]?
Parameters
None
Examples
MEAS:CURR? FETC:CURR:DC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT?
MEASure:CURRent2?
Agilent 66309B/D only
This query measures the output current at the auxiliary output. Output 2 measurements are calculated
from a total of 2048 readings taken at a 15.6 microsecond sampling rate. These parameters are fixed.
Query Syntax
MEASure[:SCALar]:CURRent2[:DC]?
Parameters
None
Examples
MEAS:CURR2? FETC:CURR2:DC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT2?
MEASure:CURRent:ACDC?
FETCh:CURRent:ACDC?
Agilent 66311B/D, 66309B/D only
These queries return the ac+dc rms output current.
Query Syntax
MEASure[:SCALar]:CURRent:ACDC?
FETCh[:SCALar]:CURRent:ACDC?
Parameters
None
Examples
MEAS:CURR:ACDC? FETC:CURR:ACDC?
Returned Parameters
<NR3>
Related Commands
MEAS:VOLT:ACDC?