Preparing the Processors
2-96800-A2-GN22-30 January 1997
Preinstallation Steps for the Automatic Backup and Restore Package
To prepare the third hard disk for installation on the System 5000, refer to Figure 2-4 and perform
the following steps:
1. Locate the terminating resistor socket marked CN6 and remove the terminating resistor, if
there is one present. The System 5000 does not use a terminating resistor.
2. Locate the jumper switch block marked as CHN1 and set the jumpers as shown in
Figure 2-4.
3. Locate the jumper switch block marked as CHN7 and set the jumpers as shown in
Figure 2-4. The CHN7 switch block must set the drive’s SCSI ID to 2.
Power
Connection
Data
Connection
CNH7
CNH1
494-14505-01
Terminating Resister Socket
(must be empty)
SCSI
ID
1
2
CNH6
Figure 2-4. Second and Third Hard Disk Jumper Settings