A SERVICE OF

logo

COMSPHERE 6800 Series Network Management System
5-92 January 1997 6800-A2-GN22-30
Type the starting I/O address and strike the ENTER key or
type Q to cancel installation. Striking the ENTER alonewill
select the default.
For the starting I/O address,
TYPE: 2B0
PRESS: Enter
6. The system prompts for the starting memory address:
Please enter the following system configuration information
for the IPC-900 Board:
The available starting controller memory addresses for the
IPC-900 Board are :
A0000 default A2000 A4000 A6000 A8000 AA000 AC000
AE000 B0000 B2000 B4000 B6000 B8000 BA000 BC000 BE000 C0000
C2000 C4000 C6000 C8000 CA000 CC000 CE000 D0000 D2000 D4000
D6000 E0000 E2000 E4000 E6000 E8000 EA000 EC000 EE000
Type the starting controller memory address and strike the
ENTER key or type Q to cancel installation. Striking the
ENTER alone will select the default.
For the Starting memory address,
TYPE: D2000
PRESS: Enter
7. The system displays the following information before seeking verification:
**********************************************
Board Configuration:
Ports Card Type = IPC-900
Interrupt number = 5
I/O ports Starting address = 2B0
Controller Memory Starting address = D2000
**********************************************
Is this configuration acceptable? (y or n)
If these values are correct, indicate yes as follows:
TYPE: y
PRESS: Enter
If the values are incorrect, indicate no as follows:
TYPE: n
PRESS: Enter
to reenter the values.
8. At this point, the installation script modifies some system configuration files and rebuilds
the UNIX operating system. This takes a few minutes.