A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-564test data-module
8
Error Messages
If the location identifier entered is not valid, the following message will be
displayed:
Command aborted; please try later
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
Output
For the following output example, assume that the command that was entered is
"test customer-alarm 02a".
Feature Interactions
None.
test data-module
This command allows the technician to test a data module or a data channel.
Port The port address (cabinet-carrier-slot) of the maintenance object
that is being reset.
Maintenance Name The maintenance name will always be CUST-ALM.
Alt. Name Not applicable.
Test No. The test number will always be 115.
Result The result of the individual test -"PASS," "ABORT," "FAIL.”
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test customer-alarm 02A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A CUST-ALM 115 PASS
Command Successfully Completed