DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-352set options
8
PMS log printer (PMS-LOG)
Primary CDR Link (PRI-CDR)
Secondary CDR Link (SEC-CDR)
SPE Select Switches (SPE-SELEC)
Synchronization (SYNC)
System Communication Interface (PI-SCI)
System Printer (SYS-PRNT)
TDM Clock (TDM-CLK)
Tone Generator Circuit Pack (TONE-BD)
Field Help
Since all fields on the first page may have the same values, then pressing HELP in
any field on the first page presents the following field help message:
m(inor) n(o) r(eport) w(arning) y(es)
The following is a description of the values:
All fields on page 2 may have the same values. Pressing
HELP in any field on
page 2 gives the following field help message:
Enter alarm group number: 1 to 4
The alarm group number is a way of distinguishing four different groups of
alarms. These alarm groups allow the user to specify that alarms in different
groups are handled differently from those in other groups.
Field Error Messages
All of the fields on the first page allow the same values. Only one error message
is printed for all first page fields. If the value is not one of the listed characters
(m,n,r,w,or y) then the following message is displayed:
"X" is an invalid entry; please press
HELP key
m(inor) Downgrade the major alarm to a minor alarm and report the alarm to
INADS.
n(o) Do not log the alarm or report it to INADS.
r(eport) Downgrade the alarm to a warning and report the warning to INADS.
w(arning) Downgrade the alarm to a warning, log it but do not report the alarm to
INADS.
y(es) Log and report the alarm to INADS.