![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/df/9dfe4cef-efc3-449e-af1c-937cc60d7a6c/9dfe4cef-efc3-449e-af1c-937cc60d7a6c-bg9c6.png)
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1559UDS1-BD (UDS1 Interface Circuit Pack)
10
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU Module
administration. The
Near-End CSU Type
field on the
add
ds1
form has been administered as
integrated
but the
DS1 circuit pack is not a TN464F or later suffix UDS1
board.
1. If the CSU Module is to be used, and the
Near-End
CSU
type field is set to
intergrated
to allow for CSU
Module administration, remove the circuit pack and
replace with a TN464F or later suffix board.
Otherwise, use the
change ds1
command to
change the
Near-End CSU Type
field to
other
.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209)
failed.
1. Repeat the test using the
test ds1-loop PCSS
ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the
TN464F circuit pack. 3) Run this test again.
Table 10-460. TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page