DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-459status health
8
Time Source The current timing source is displayed. The display values for this field
vary according to the timing source selected. If the site has administered
the optional Stratum-3 hardware, "external" will be displayed under
normal operating conditions and "internal" will be displayed when an
internal source, such as a tone clock, is used. Primary and secondary
timing sources must be administered when using the Stratum-4 option.
"primary" is displayed when the primary administered source is in use,
and "secondary" is displayed when the administered secondary source
is in use. When neither the primary or secondary sources are in use,
"local" will be displayed.
# Logins The number of current users is displayed.
Cab The assigned cabinet number, ranging from 1 to the highest cabinet
number in the system, is displayed on the screen.
Emerg Trans The current setting of the emergency transfer switch on the maintenance
board is indicated for each cabinet. Five options are available: auto-on
("auto+" or "a+"), auto-off ("auto-" or "a-"), "on", "off", and "n.a.". Normally,
the "auto+" or "auto-" option is enabled. In this state, emergency transfer
will be activated automatically upon cabinet failure (The "+" indicates
that emergency transfer is currently activated, while the "-" indicates that
emergency transfer is currently not activated). When "on" is displayed,
emergency transfer is automatically activated. The "off" option shows
that the cabinet is prevented from activating emergency transfer. In a
system equipped with duplicated SPEs, the switch settings for both
processors of the PPN (cabinet 1) will be displayed. In this case, "auto+"
will be abbreviated "a+", "auto-" will be abbreviated "a-", and "off" will be
abbreviated as "of". "on" will not be changed. If "n.a." is displayed, the
emergency transfer switch setting is not available.
Mj The individual number of major alarms associated with the cabinet is
indicated. An asterisk is used to fill the field when the number exceeds
99.
Mn The individual number of minor alarms associated with the cabinet is
indicated. An asterisk is used to fill the field when the number exceeds
99.
Wn The individual number of associated with the cabinet is indicated. An
asterisk is used to fill the field when the number exceeds 99.
PNC Current Port Network Connectivity (PNC) status for each of the port
networks within a cabinet is displayed. When multiple port networks exist
within a cabinet, Carriers A, B, and C are listed first and separated from
Carriers D and E by a slash (for example, up/up). PNC status of a port
network is determined on the basis of availability of the Expansion
Archangel Link (EAL). An "up" denotes that the EAL is available. When
the EAL is not available, then a "dn" (down) is displayed.
Time of Day The current time of day acquired from the system is displayed.