Xantrex Technology Link 1000 Portable Generator User Manual


 
Reading Error Codes
50
E012 Battery voltage sense lead open
(Link 1000)
Check the fuse or any other connections in the voltage
sense lead (blue wire) to the battery.
E013 Spare
E014 Inappropriate charged voltage selected for the
sensed voltage
(Link 1000)
This code appears if the Charged Voltage parameter is
above 20 V and the sensed voltage is below 20 V, or if
the sensed voltage is above 20 V and Charged Voltage
parameter is below 20 V.
This code will help you avoid an incorrect setup.
E015 Incoming AC polarity reversed
(Inverter/charger error)
Check the incoming AC wiring for reversed polarity
(positive and neutral reversed).
Consult a qualified electrician if you do not know how
to diagnose and correct this condition.
0L Link 1000 reading out of range
(Link 1000)
Error
Code Meaning