Xantrex Technology Link 1000 Portable Generator User Manual


 
About Link 1000 Settings
26
To change the Charged Current Percentage:
1. Press and hold
SET until SEL appears.
2. Press
SEL twice. The LED comes on and 002 is
displayed.
3. Press and hold
SET.
The display moves up in one percent steps until 7
percent is displayed. The display then rolls over and
starts counting up from 1 percent.
4. Release
SET when the appropriate percentage appears.
Changing the Time Remaining Setting
The Link 1000 has four ways of calculating the amount of
operating time that remains. You can select:
Present consumption level
A four minute average
A sixteen minute average
A thirty-two minute average
The best setting depends on your type of installation.The four
minute average is appropriate for most installations.
To change the Time Remaining setting:
1. Press
SET until SEL appears.
2. Press
SEL four times until the LED comes on and
001 appears.
3. Press
SET until the number you want appears. The
display moves up in 1 unit steps with choices of:
4. Release
SET when the value you want appears.
000
Present consumption
001
4 minute average
002
16 minute average
003
32 minute average