Viking Access Systems T21 Swimming Pool Gate Alarm User Manual


 
TECHNICAL SUPPORT 1 800 908 0884
17
Limit Switch Connections
NC
NO
COM
NC
NO
COM
Cam Wheel
Red
Black
Green
White
Left Limit 
Switch
Right Limit Switch
1. Setup the limit switches manually at the desired open and close position.
2. Allow the gate operator to run a full open and close cycle (from limit to limit)
without interruption.
Note: During the first full open and close cycle: The gate operator doesn’t slow
down prior to reaching its limits. During subsequent cycles: The gate operator will
slow down prior to reaching its limits.
3. Verify that the gate opens and closes to the desired position.
To change the open or close limit position(s) the following
steps MUST BE taken:
A. Reset the gate operator by actuating both limit
switches at the same time
B. Repeat steps 1,2 and 3.
Opening/Closing Setup
Fast
Slow
Slow
LIMIT SWITCH SET-UPLIMIT SWITCH SET-UP
The Limit Switches
are wired as shown.
Additional Guide Pin
holes are provided to
allow orientation of
the Limit Cams away
from the Swing Arm.