Anritsu 681XXC Portable Generator User Manual


 
5-28 681XXC OM
Model 68137C w/Option 15A Serial No. ____________________ Date ___________
Model 68137C with Option 15A High Power
(without Option 2 Step Attenuator)
Power Level Accuracy *
(CW Frequency = 5.0 GHz)
Set Power Measured Power
+17 dBm
+16 dBm
+15 dBm
+14 dBm
+13 dBm
+12 dBm
+11 dBm
+10 dBm
+ 9 dBm
+ 8 dBm
+ 7 dBm
+ 6 dBm
+ 5 dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
_________dBm
* Specification is ±1.0 dB.
Power Level Flatness (Step Sweep)
Set Power Max Power Min Power Variation **
+ 17 dBm _________dBm __________dBm _________dB
** Maximum variation is 1.6 dB.
Power Level Flatness (Analog Sweep)
Set Power Max Power Min Power Variation ***
+ 17 dBm _________dBm __________dBm _________dB
*** Maximum variation is 2.0 dB (typical, not a specification).
Table 5-3. Power Level Accuracy and Flatness Test Record (10 of 27)
OPERATION POWER LEVEL ACCURACY
VERIFICATION AND FLATNESS TESTS