Tektronix TDS 420A Sprinkler User Manual


 
Command Descriptions
2–274
TDS Family Oscilloscope Programmer Manual
TRIGger :
:
MAIn :
<Space>
PLUSOne
?
MINUSOne
COMMunication
AMI
EEYEdiagram
:
PULSEForm
PLUSOne corresponds to the Isolated +1 on the front panel menu. This is the
default value.
MINUSOne corresponds to the Isolated –1.
EYEdiagram corresponds to Eye Diagram.
TRIGGER:MAIN:COMM:AMI:PULSEFORM PLUSONE
selects the AMI pulseform to the Isolated +1.
TRIGger:MAIn:COMMunication:AMI:THReshold:HIGH
TDS 500C & 700C Only
Sets or queries the AMI communication trigger’s high threshold value in volts.
Trigger
TRIGger:MAIn:COMMunication:AMI:THReshold:HIGH <NR3>
TRIGger:MAIn:COMMunication:AMI:THReshold:HIGH?
TRIGger :
:
MAIn :
<Space>
?
COMMunication
HIGH
:
THReshold
<NR3>
AMI
:
<NR3> is the high value of the threshold. The unit of measure is volts. The
default is +0.5 volts.
TRIGGER:MAIN:COMM:AMI:THRESHOLD:HIGH 2.8 E–2
sets the high threshold to 28 milliVolts.
Arguments
Examples
Group
Syntax
Arguments
Examples