Tektronix TDS 420A Sprinkler User Manual


 
Command Descriptions
2–106
TDS Family Oscilloscope Programmer Manual
*DDT
Allows the user to specify a command or a list of commands that are executed
when the instrument receives a *TRG command or the GET GPIB interface
message. *DDT is just a special alias that *TRG uses.
Miscellaneous
ALIAS:DEFINE, *TRG
*DDT { <Block> | <QString> }
*DDT?
<QString>
*DDT
<Space>
?
<Block>
<Block> or <QString> is a complete sequence of program messages. The
messages can contain only valid commands that must be separated by semico-
lons and must follow all rules for concatenating commands (see page 2–4). The
sequence must be 80 characters. <Block> format is always returned as a query
response.
*DDT #0ACQUIRE:STATE RUN;BELL<EOI>
specifies that the acquisition system will be started and the bell rings each time a
*TRG command is sent.
DELEte:SETUp (No Query Form)
Removes stored setups from memory and initializes the location with the factory
default setup.
NOTE. The setup information cannot be recovered once it has been deleted.