Message Meaning
If the hot tub water is more than 20°F cooler than the
temperature setpoint, jets pump #1 and heater will
automatically activate to provide freeze protection. The
hot tub will stay in this mode until the water
temperature reaches 15 degrees below the set
temperature then turns off. No corrective action is
necessary.
FLOW SWITCH (Heater is deactivated. The lter/
circulation may also be deactivated). Proper ow of
water is inhibited or a ow switch has malfunctioned.
Check for proper water level and for clogged lter
(pages 42-43). Contact your Sundance Spas dealer or
qualied service technician.
*Note: This message can also appear if the pump has
not regained prime after the hot tub has been drained
and relled. If you suspect that this is the case, see the
instructions on page 52 under “pump does not
operate and icon does.”
Circuit board temperature has exceeded acceptable
limit. This message will disappear when the circuit
board temperature drops below acceptable limit. If
condition persists, provide shade for the side with the
hot tub equipment.
FREEZE PROTECTION
A potential freeze condition has been detected. No
action is required. Jets pump(s) operate until the hot
tub is out of danger. Note: This error commonly occurs
when the hot tub is rst lled because tap water is
often very cold.
Communication between the control panel and/
or remote control panel and circuit board is faulty.
Contact your Sundance Spas dealer or qualied
service technician.
*