Page 14
880 SERIES
6.0 Maxxus Power Requirements
Sundance
®
hot tubs are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
However, they are shipped factory congured for their most common
preferred electrical connection as follows:
• North American 60 Hz Model: 240 VAC/60A
If you prefer, a qualified technician can perform a minor circuit board
modication that allows the hot tub to operate on a different electrical
service (see table below).
North American 60 Hz Maxxus
240V/50A* 240V/60A**
Voltage 240 VAC 240 VAC
Max. Current Draw 38A 48A
Number of Wires 3 3
Circuit Breaker (2-Pole) 50A* 60A**
*
In this conguration, the heater
will not operate while any two jets
pumps are running.
**
In this conguration the heater
will operate while any two jets pumps
and the blower are running but will not operate when all three jets
pumps are running.
North American 60 Hz Maxxus
240V/50A* 240V/60A**
Voltage 240 VAC 240 VAC
Max. Current Draw 38A 48A
Number of Wires 3 3
Circuit Breaker (2-Pole) 50A* 60A**
*
In this conguration, the heater will not operate while any two jets
pumps are running.
**
In this conguration the heater will operate while any two jets pumps
and the blower are running but will not operate when all three jets
pumps are running.