Page 18
880 SERIES
Important Heater Details:
• The maximum temperature for which the hot tub can be set is
104°F (40°C) and the minimum is 80°F (27°C).
• For Cameo and Optima hot tubs powered with a 40 amp service,
turn off jets pump #1 and jets pump #2 to operate heater.
• Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
• The heater operates until the water reaches the programmed “set
temperature”, then turns off. The heater will reactivate after the
water cools to approximately 1° below the “set temperature.”
8. Place Cover On Hot Tub
• Keeping the insulating cover in place anytime the hot tub is not in
use will reduce the time required for heating, thereby minimizing
operating costs.
• The time required for initial heat-up will vary depending on the
starting water temperature.
DANGER: Risk of injury, always check water
temperature carefully before entering hot tub!
Decontamination Procedure (Steps 9-15)
Steps 9-15 below are only required when sanitizer levels are unstable
after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer
levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after
performing steps 1-6 above.
9. Add 2.5 ounces of sodium dichlor for every 100 gallons of water.
Refer to the table (page 19) for approximate water ll capacity by
model.
CAUTION: Never add chlorine tablets (trichlor) to
your hot tub for any reason! This chemical may
damage components within your hot tub and void the
manufacturer warranty.