MODEL RGX305, RGX305D
I
I
Tester polarity i
Yellow 1 Red
Green 1 Brown
-I
I
I
I
Yellow j
One wire: OR 1
700K - 1 MZ
72K - 120KSl
65K - 10KC
Another: 00
7
One wire: 0.0,
400K - 500KG ’ 72K - 120KR
! 6%
- lOK,o,
i Another: m
Red
-
I
-
250K-300KR ’ 00
, 400K - 500KQ
1
-
-
I 130K - 140Kn
00
220K - 250KR
*Upper rows are for the 220, 230, 240U specifications; lower rows for the 110, 120U specifications
and the dual voltage type.
Table 9- I
White
Green
-
250K-300KC! ’ -
-
I
m
; 45K- 50KR
-
130K - 140KC!
-
c.2
45K - 50K!C?
-
600K-1MR - 70K-llOK,c ’ - 7K - 9.5KR
-
SOOK - 500KS ! 70K - 1lOKQ
-
6.5K - 8.5KS1
Brown
-
400K - 50OKr1 40K-46KQ 1 =
I -
I
-
1 250K - 300K-r; 40K - 46K,o,
00
-
I
9-4-3 IDENTIFYING AUR TROUBLE by MOUNTING AVR in THE GENERATOR and OPERATING AUR
SCR or transistor damage cannot be detected by simply looking at the AVR or checking the lead resistances. Check it by
mounting the suspectedly faulty AVR in a normal generator, or mount a normal AVR in a generator which fails to generate
voltage.
- 37 -