4-9. AIR COMPRESSOR CONNECTIONS
This unit delivers 12 cfm of air at a pressure of 100 psi
whenever the engine is running. A 1/2 in. NPT fitting for
air compressor connections is provided on the top cover
of the unit.
To make connections to the air compressor, obtain and
install a quick-connect connector onto the air compres-
sor fitting.
4-10. ETHER STARTING AID (Optional)
This unit is shipped without the ether cylinder. Before
this device is operational, an ether cylinder must be ob-
tained and installed. To install the ether cylinder, pro-
ceed as follows:
WARNING: IMPROPER HANDLING OR EX-
POSURE TO ETHER can seriously harm
your health.
Follow the manufacturer’s safety instructions
on the cylinder when handling ether compo-
nents.
IMPORTANT: Before installing the ether cylinder, clean
nozzle on ether cylinder and fitting into which the ether
cylinder is inserted. If dirt is present in either of these ar-
eas, the system may not work.
1. Open and secure right rear side door.
2. If applicable, remove protective cap from ether
valve, or remove old ether cylinder from unit.
3. Loosen cylinder clamp, install ether cylinder, and
tighten clamp.
IMPORTANT: After installing or replacing ether cylin-
der, do not use or test ether start system for at least 10 to
15 minutes to allow particles in fuel to settle to prevent
atomizer plugging.
4. Using a liquid soap and water solution, check all
ether start system connections for leaks. If a leak
exists, escaping gas will produce bubbles in the
solution.
5. Close and secure side door.
Ref. ST-164 613-A
Figure 4-4. Terminal Strip 3T Information