3. Proper placement of the equipment on the trailer to
insure stability side to side and front to back when
being moved and when standing by itself while
being operated or serviced.
4. Typical conditions of use, i.e., travel speed; rough-
ness of surface on which the trailer will be operated;
environmental conditions.
5. Conformance with federal, state and local laws
(1)
(1) Consult applicable federal, state and local laws regarding specif-
ic requirements for use on public highways.
READ the engine operating and maintenance
instructions supplied with this machine.
FUEL (
GASOLINE FUEL ONLY)
Fil the fuel tank with clean, fresh, lead-free gasoline. Observe fuel
gauge while filling to prevent overfilling.
INSTALLATION
A-4 A-4
EAGLE™ 10,000
BATTERY CONNECTIONS
Use caution as the electrolyte is a strong acid that can
burn skin and damage eyes.
------------------------------------------------------------------------------------------
This welder is shipped with the negative battery cable discon-
nected. Make sure that the Engine Switch is in the “OFF” posi-
tion and attach the disconnected cable securely to the negative
battery terminal before attempting to operate the machine. If the
battery is discharged and does not have enough power to start
the engine, see the battery charging instructions in the Battery
section.
NOTE: This machine is furnished with a wet charged battery; if
unused for several months, the battery may require a booster
charge. Be careful to charge the battery with the correct polarity.
WELDING OUTPUT CABLES
With the engine off, connect the electrode and work cables to the
studs provided. These connections should be checked periodi-
cally and tightened if necessary. Loose connections will result in
overheating of the output studs.
When welding at a considerable distance from the welder, be
sure you use ample size welding cables. Listed below are cop-
per cable sizes recommended for the rated current and duty
cycle. Lengths stipulated are the distance from the welder to
work and back to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing cable volt-
age drop.
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
0-100 Ft.
(0-328 m)
100-200 Ft.
(328-656 m)
200-250 Ft.
(656-820 m)
225 Amps
100% Duty Cycle
1 AWG
1 AWG
1/0 AWG
CAUTION
OIL
The EAGLE 10,000 is shipped with the engine
crankcase filled with SAE 10W-30 oil. Check the oil
level before starting the engine. If it is not up to the full
mark on the dip stick, add oil as required. Make certain
that the oil filler cap is tightened securely. Refer to the
engine Owner’s Manual for specific oil recommenda-
tions.
LUBRICATION SYSTEM CAPACITY
(INCLUDING FILTER)
Kohler CH23S - 2.0 Quarts (1.9 Liters)
VEHICLE MOUNTING
Improperly mounted concentrated loads may cause unstable
vehicle handling and tires or other components to fail.
Only transport this Equipment on serviceable vehicles which
are rated and designed for such loads.
Distribute, balance and secure loads so vehicle is stable
under conditions of use.
Do not exceed maximum rated loads for components such as
suspension, axles and tires.
Mount equipment base to metal bed or frame of vehicle.
Follow vehicle manufacturer’s instructions.
------------------------------------------------------------------------------------------
WARNING
Stop engine while fueling.
Do not smoke when fueling.
Keep sparks and flame away from
tank.
Do not leave unattended while fueling.
Wipe up spilled fuel and allow fumes
to clear before starting engine.
Do not overfill tank, fuel expansion
may cause overflow.
--------------------------------------------------------------------------------
WARNING
GASOLINE
can cause fire
or explosion.
Damage to the fuel tank may cause
fire or explosion. Do not drill holes
in the EAGLE 10,000 base or weld to
the EAGLE 10,000 base.
-----------------------------------------------------------------------
WARNING
CAUTION
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC