Operating instructions
149 443 103
C 4.74
Operating the implements
6
5
Bild_C185
ATTENTION
Turn on the starting safety switch (6) only at
low engine speed.
- Set the rotary knob (5) to 0.
- Release the lock at the starting safety switch (6) and
depress the switch. The indicator in the switch comes
on.
ATTENTION
After the speed of the motor was raised, the
oil flow may only be raised slowly.
- Turn the rotary knob (5) for adjusting the oil flow from
0 to 100 litres/min until the performance of the imple-
ment is reached.
NOTE
The implement coded plug specifies the maxi-
mum oil flow for the related implement (for
safety reasons).
The number 11 on the ring corresponds to the maxi-
mum oil flow specified by the coding.