Agilent Technologies 5951-2826 Tiller User Manual


 
General Information 11
Table 1-1. Specifications (continued)
DERATED CURRENT DETAIL
6060B 6063B
CONSTANT CURRENT MODE
Ranges
Low Range: 0 to 6 A 0 to 1 A
High Range: 0 to 60 A 0 to 10 A
Accuracy (after 30 sec wait): ± 0.1% ± 75 mA ± 0.15% ± 10 mA
both ranges both ranges
Regulation: 10 mA both ranges 8 mA both ranges
CONSTANT RESISTANCE MODE
Ranges
Low Range: 0.033 to 1
0.20 to 24
Middle Range: 1 to 1000
24 to 10,000
High Range: 10 to I 0,000
240 to 50,000
Accuracy
Low Range:
±
0.8% ± 8 m
± 0.8% ± 200 m
with
6 V at input with
1 A at input
Middle and High Ranges: ± 0.3% ± 8 mS ± 0.3% ± 0.3 mS
with
6 V at input with
24 V at input
CONSTANT VOLTAGE MODE
Range: 0 to 60 V 0 to 240 V
Accuracy: ± 0.1% ± 50 mv ± 0.12% ± 120 mV
Regulation: 10 mV (remote sense), 10 mV (remote sense)
40 mV (local sense) 40 mV (local sense)
TRANSIENT OPERATION
Modes: Continuous, pulsed, or toggled
Continuous Mode
Freq Range: 0.25 Hz to 10 kHz
Freq Accuracy: 3%
Duty Cycle Range: 3% to 97% (0.25 Hz to 1 kHz);
6% to 94% (1 kHz to 10 kHz)
Duty Cycle Accuracy: 6% of setting ± 2%
Pulsed Mode
Pulse Width: 50 µs ± 3% minimum; 4 s ± 3% maximum