Tektronix 071-1631-04 Portable Generator User Manual


 
Specifications
80 AFG3000 Series Quick Start User Manual
Resolution 1 μHz or 12 digits
Accuracy (Stability) ±1 ppm, 0 °C to 50 °C (except Arb)
±1 ppm ±1 μHz, 0 °C to 50 °C (Arb)
Accuracy (Aging) ±1 ppm/year
Phase (except DC, Noise, Pulse)
Range
3
–180.00° to +180.00°
Lead Delay (Pulse)
Range (Continuous Mode) 0 ps to Period
Range (Triggered/Gated
Burst Mode)
0 ps to Period [Pulse Width + 0.8 * (Leading Edge Time + Trailing Edge Time)]
Resolution 10 ps or 8 digits
Amplitude (50 Ω) AFG3021B/AFG3022B AFG3101/AFG3102 AFG3251/AFG3252
Range
4,
5
10 mV
p-p
to 10 V
p-p
20 mV
p-p
to 10 V
p-p
50 mV
p-p
to 5 V
p-p
Accuracy ±(1% of setting +1 mV) (1 kHz sine waveform, 0 V offset, >10 mV
p-p
amplitude)
Resolution 0.1 mV
p-p
, 0.1 mV
rms
, 1 mV, 0.1 dBm or 4 digits
Units
6
V
p-p
, V
rms
, dBm, and Volt (High Level and Low Level)
Output Impedance 50 Ω
Isolation 42 V
pk
maximum to earth
DC Offset (50 Ω) AFG3021B/AFG3022B AFG3101/AFG3102 AFG3251/AFG3252
Range
7
±5 V
pk
ac + dc into 50 Ω ±5 V dc into 50 Ω ±2.5 V dc into 50 Ω
Accuracy
8
±(1% of |setting| +5 mV + 0.5% of amplitude (V
p-p
))
Resolution 1 mV
Internal Noise Add
Range 0.0% to 50% of amplitude setting (V
p-p
) of signal waveform
Resolution 1%
1. Triggered/Gated Burst Mode:
AFG3021B/AFG3022B, 1
μHz to 12.5 MHz
AFG3101/AFG3102, 1
μHz to 50 MHz
AFG3251/AFG3252, 1
μHz to 120 MHz
2. Triggered/Gated Burst Mode:
AFG3021B/AFG3022B, 1 mHz to 6.25 MHz
AFG3101/AFG3102, 1 mHz to 25 MHz
AFG3251/AFG3252, 1 mHz to 60 MHz
3. Resolution: 0.01° (sine), 0.1° (other standard waveforms)
4. AFG3021B/AFG3022B: 20 mV
p-p
to 20 V
p-p
into open circuit load
AFG3101/AFG3102: 40 mV
p-p
to 20 V
p-p
into open circuit load
AFG3251/AFG3252: 100 mV
p-p
to 10 V
p-p
into open circuit load
5. AFG3251/AFG3252 (frequency range: >200 MHz to 240 MHz): 50 mV
p-p
to 4 V
p-p
into 50 Ω, 100 mV
p-p
to 8 V
p-p
into open circuit load
6. dBm is used only for sine waveform, and V
rms
is not available for Arb and Noise waveforms.
7. AFG3021B/AFG3022B and AFG3101/AFG3102: ±10 V
pk
ac + dc into open circuit load
AFG3251/AFG3252: ±5 V dc into open circuit load
8. AFG3021B/AFG3022B and AFG3101/AFG3102: Add 0.5 mV per °C for operation outside the range of 20 °C to 30 °C.
AFG3251/AFG3252: Add 2.0 mV per °C for operation outside the range of 20 °C to 30 °C.