14
J-300
Export J-335, J-345, J-355, J-365, J-375 and J-385 Models (50 Hz)
230V/20A* 230V/30A** 230V/40A***
RCD Breaker: 20A 30A 40A
Number of Wires: 3 3 3
Frequency: 50 Hz 50 Hz 50 Hz
Current Draw: 15A 23A 29A
Wattage: 3.5 kW 5.3 kW 6.7 kW
*
In 20A conguration, the heater will not operate while either jets
pump is running. This is the factory setting.
**
In 30A conguration, the heater will operate while one jets pump
is running.
***
In 40A conguration the heater will operate while both jets pumps
are running.
Export J-315 and J-325 Models (50 Hz)
230V/20A* 230V/30A**
RCD Breaker: 20A 30A
Number of Wires: 3 3
Frequency: 50 Hz 50 Hz
Current Draw: 15A 21A
Wattage: 3.5 kW 4.8 kW
*
In 20A conguration, the heater will not operate while the jets
pump is running. This is the factory setting.
**
In 30A conguration, the heater will operate while the jets pump is
running.