31
J-300
11.3 Programming the Change Filter Timer
Included within the Primary Filtration Menu, is the Change Filter feature.
To make changes to the change lter timer or to reset it, follow the steps
below.
A. Press the Menu (
) button once to enter the Primary Filtration
Menu. The LED screen will display “PF.”
B. Press the Warmer ( ) button to scroll through the Primary
Filtration cycles. After the last cycle, “PF8,” the LED screen will
display the number of days remaining or zero, Figure 3.
Note: If you press the Warmer ( ) button after the number of days
remaining you will revert back to the “PF” menu. You will need to repeat
step B to re-enter the menu.
C. Press the Jets Pump 1 ( ) button to access the Change Filter
Timer. The display on the LED screen will blink once to indicate that
the system is ready to accept changes.
D. Pressing the Warmer ( ) or Cooler ( ) button will add or
subtract days in increments of 10 days. The range is from 0 to 180
days.
E. Once you select the number of days, press the Jets Pump 1 ( )
button to conrm the selection. The display of the LED screen will
blink twice to indicate that the changes have been accepted. You
must press the Jets Pump 1 ( ) button to conrm your selection
or the current settings will remain active.
F. When the countdown timer reaches “0,” the LED
display will ash between “CF” (Figure 4) and the water
temperature. At this time the lters must be replaced or
cleaned and the timer reset.
Note: If no button is pressed within 5 seconds of each selection the
screen will revert back to the Main Menu and the current settings will
remain active.
OR
PRESS
PRESS
PRESS
Figure 3