Dimension One Spas 01513-192 Hot Tub User Manual


 
Aquatic Fitness System
2005 Owner’s Manual
39
Troubleshooting Guide
Heating System
Symptom Problem Corrective Action
1. Temperature setting is too low 1. Turn up the thermostat
2. Dirty filter 2. Clean filter
Does not heat
3. Flow switch out of adjustment 3. Call for service
1. Temperature setting is to high 1. Turn down the thermostat Too hot
2. High limit tripped 2. Call for service
Flashing temperature of 34°F or
134°F appears on the display
Possible temperature sensor failure Call for service
Electrical System
Symptom Problem Corrective Action
Will not turn on – in any mode No power Check circuit breaker and/or GFCI
Turns on by itself Normal automatic daily power
filtration, or anti-freeze cycle
No action required
Light is out Burned out bulb Replace bulb
1. Automatic 30-minute timer has
shut pump off
1. Push JETS pad again to start
another 30-minute cycle
Pump shuts down unexpectedly
while in use
2. Motor over-heated and
automatic protective device
has shut down pump(s)
2. If pump(s) will not restart when
JETS pad is pushed, call for
service
Make sure that the equipment
panel vent area is not blocked.
Vent blockage can cause
serious damage to your
equipment.
1. Check water level
2. Clean filter
If problem persists:
1. Turn off power
2. Restart the system
If problem persists:
3 flashing LEDs appear on the
Top Side Control
Possible sensor errors
Call for service
Water System
Symptom Problem Corrective Action
Pulsating jets Water level too low Fill with water to 1” to 2” (2 to 5
centimeters) above the bottom of
the tile line
1. HydroTherapy Jets closed 1. Open Jets
2. Diverter Valve turned 2. Turn the Diverter Valve
clockwise or counter
clockwise
3. Dirty Filter 3. Clean Filter
4. Air lock 4. Loosen pump union to allow air
to escape
No Jet Action, or action is poor
5. Gate valve closed 5. Open gate valve
1. Check TA/pH
2. Test and adjust
The water is cloudy or has a smell The water has a chemical
imbalance.
3. Change Water if necessary