Dimension One Spas 01513-192 Hot Tub User Manual


 
Aquatic Fitness System
2005 Owner’s Manual
15
Jets 2 and Jets 3 Buttons
JETS 2 and JETS 3 Buttons: Press the appropriate button once to turn on
Pumps 2 or 3. The pumps work independently, thus allowing you to control
the total volume of water pumped to the Swim Jets. Pressing either button a
second press will turn that pump(s) off.
A built-in timer will shut the pump(s) off after 20 minutes of operation unless
you manually shut them off earlier. The Jets 2 or Jets 3 Indicator light will be lit
next to the Jets 2 or Jets 3 Button whenever that Jet is running.
Pumps 2 and 3 provide high volume water flow to the Swim Jets.
If you are operating with a 60-amp service for heat and pumps, the heater will turn
off if any of the pumps are operated at high speed. If you are running a separate 50-
amp service for heat and a separate 50-amp service for the pumps, you can
continue to heat your water while operating the pumps at high speed.
Light Button
Push the Light Button to control your Dynamic LED lighting. This includes both
Spa lights, which are synchronized to operate together. The lights have three
basic Color Effects you can choose. Simply press the Light Button until you
find the one you want. The Color Effects are:
Color Fade Slow: This sequence rotates through all colors
approximately once per minute.
(Start up default)
Color Hold: Hold on any of the colors.
Color Fade Fast: This sequence rotates through all colors
approximately three times per minute.
The default Color Effect is Color Fade Slow. Use the Light Button to change
Color Effects as follows:
Start on Color Fade Slow (default)
Turn off for 1 second, back on again for Color Hold
Turn off for 1 second, back on again for Color Fade Fast
Turn off for 1 second, back on again for Color Hold
Turn off for 1 second, back on repeats to Color Fade Slow
Turn off for 5 or longer: start on Color Fade Slow
For your convenience and cost savings, the lights will automatically turn off after
one hour. To reactivate the lights after the timer has shut them off, simply press the
Light Button again. The lights will always start in the Color Fade Slow sequence
after they have been off for more than 5 seconds. This ensures they always remain
synchronized in multiple light spas.